System-Level Specifications
Solar Cell Characteristics
Cell Type Triple junction solar cell
Cooling System Passive convection cooling with aluminum heat-sink
Cell Size 30 mm2
Temperature coefficient -0.12% per °C
System Frame Set
HCPV module power rating (CRC) 300 WpDC (1)
Cell-units per module 30
Power per cell-unit 10 WpDC (1)
Efficiency 30%
Acceptance tracking angle 1.8°
Voc 91.1 V
Isc 4.1 A
Fuse rating 8.0 A
Total frame-set output power (CRC) 2.85 kWpDC
Number of HCPV modules per frame-set 10
Frame-set footprint 7.1 ft x 32.8 ft / 2.165 m x 10.0 m
Frame-set row spacing 7.1 ft / 2.165 m
Weight 2,200 lbs / 998 kg
3.78 per ft2 / 18.44 kg per m2
Source strings per frame-set 2
Source String DC output specifications
Voltage at MPP 410 VDC
Current at MPP 3.51 A
Fuse rating (per NEC §690) 6.0 A
Tracker
Sealed with ultra-low evaporating lubricant
Tracking algorithm Module level power maximization
Tracking Accuracy (incl. Backlash) 0.3°
Operable global latitude range 45°S – 45°N
Range of motion
Azimuth 160°E – 160°W from South
Elevation 0° – 120° from horizon
Elevation drive motor Single stepper motor
Azimuth drive motor Single stepper motor
Installation & Environment
Ambient operating temperature -20°C to 50°C
Power connectivity Junction box at tracker frame
Inverter compatibility Compatible with standard UL 1741 Listed grid tied DC/AC inverter
Installation zoning
Wind Wind Exposure D - Max 90 mph (145 km/h) (ASCE 07-05/IBC/UBC/CBC)
Seismic Seismic Zone 4 (UBC/CBC)
Certification
UL 8703 / IEC 62108UL ListedIECGo Solar California
Controls Software & Status Monitoring
The Sunflower® control software provides closed-loop and open-loop tracking modes. Closed-loop is based on the individual module maximum solar power measurement with real-time feedback loop. Open-loop tracking is activated when a cloud shadows the Sunflower system. In this case, the feedback loop for tracking is based on continuous calibrated solar positioning data. As soon as this cloud shadowing disappears, the Sunflower modules will immediately produce power, maximizing system availability.
Control Stow-mode for wind safety at 50 mph (80.5 km/h)
Dust mitigation mode to minimize soiling
Clean mode for easy access cleaning
Database SQLite; open source in public domain (http://www.sqlite.org)
Monitoring information Module resolution status indication (DC)
Module level tracking angle indication
Frame-set level power measurement (DC)
Total field power measurement (DC)
Ambient air temperature
Wind speed
PowerPort™ Carport
Standard 37.5 feet wide CPV carport sections for compact-car and standard-car parking stalls. Each carport section covers 4 to 5 parking stalls. No column intrusion in parking stalls.
Power production per PowerPort™ section Compact parking stalls: 13.0 MWh/year (2)
Standard parking stalls: 16.2 MWh/year (2)
(1) Concentrator Reporting Conditions (+/-10%) - 900 W/m2 DNI, AM 1.5, 20°C Ambient Temperature, 4 m/s wind speed
(2) Based on a DNI of 6.9 kWh/m2/day (comparable with the DNI value for the Palm Springs area which is provided by National Renewable Energy Laboratory (NREL)

Request for Info: